ibnodes - Man Page

show InfiniBand nodes in topology

Synopsis

ibnodes [options] [<topology-file>]

Description

ibnodes is a script which either walks the IB subnet topology or uses an already saved topology file and extracts the IB nodes (CAs and switches).

Options

-C,  --Ca <ca_name>
   use the specified ca_name.
-P,  --Port <ca_port>
   use the specified ca_port.
-t,  --timeout <timeout_ms>
override the default timeout for the solicited mads.
-h,  --help
     show the usage message
--config,  -z  <config_file>
Specify alternate config file.

Default: /etc/infiniband-diags/ibdiag.conf

Local port Selection

Multiple port/Multiple CA support: when no IB device or port is specified (see the "local umad parameters" below), the libibumad library selects the port to use by the following criteria:

  1. the first port that is ACTIVE.
  2. if not found, the first port that is UP (physical link up).

If a port and/or CA name is specified, the libibumad library attempts to fulfill the user request, and will fail if it is not possible.

For example:

ibaddr                 # use the first port (criteria #1 above)
ibaddr -C mthca1       # pick the best port from "mthca1" only.
ibaddr -P 2            # use the second (active/up) port from the first available IB device.
ibaddr -C mthca0 -P 2  # use the specified port only.

Files

Config File

/etc/infiniband-diags/ibdiag.conf

A global config file is provided to set some of the common options for all tools.  See supplied config file for details.

Node Name Map File Format

The node name map is used to specify user friendly names for nodes in the output.  GUIDs are used to perform the lookup.

This functionality is provided by the opensm-libs package.  See opensm(8) for the file location for your installation.

Generically:

# comment
<guid> "<name>"

Example:

# IB1
# Line cards
0x0008f104003f125c "IB1 (Rack 11 slot 1   ) ISR9288/ISR9096 Voltaire sLB-24D"
0x0008f104003f125d "IB1 (Rack 11 slot 1   ) ISR9288/ISR9096 Voltaire sLB-24D"
0x0008f104003f10d2 "IB1 (Rack 11 slot 2   ) ISR9288/ISR9096 Voltaire sLB-24D"
0x0008f104003f10d3 "IB1 (Rack 11 slot 2   ) ISR9288/ISR9096 Voltaire sLB-24D"
0x0008f104003f10bf "IB1 (Rack 11 slot 12  ) ISR9288/ISR9096 Voltaire sLB-24D"

# Spines
0x0008f10400400e2d "IB1 (Rack 11 spine 1   ) ISR9288 Voltaire sFB-12D"
0x0008f10400400e2e "IB1 (Rack 11 spine 1   ) ISR9288 Voltaire sFB-12D"
0x0008f10400400e2f "IB1 (Rack 11 spine 1   ) ISR9288 Voltaire sFB-12D"
0x0008f10400400e31 "IB1 (Rack 11 spine 2   ) ISR9288 Voltaire sFB-12D"
0x0008f10400400e32 "IB1 (Rack 11 spine 2   ) ISR9288 Voltaire sFB-12D"

# GUID   Node Name
0x0008f10400411a08 "SW1  (Rack  3) ISR9024 Voltaire 9024D"
0x0008f10400411a28 "SW2  (Rack  3) ISR9024 Voltaire 9024D"
0x0008f10400411a34 "SW3  (Rack  3) ISR9024 Voltaire 9024D"
0x0008f104004119d0 "SW4  (Rack  3) ISR9024 Voltaire 9024D"

See Also

ibnetdiscover(8)

Dependencies

ibnetdiscover, ibnetdiscover format

Author

Hal Rosenstock

<  <halr@voltaire.com>  >

Info

2012-05-14 OpenIB Diagnostics