Smokeping_probes_EchoPingChargen - Man Page
an echoping(1) probe for SmokePing
Overview
Measures TCP chargen (port 19) roundtrip times for SmokePing.
Synopsis
*** Probes *** +EchoPingChargen binary = /usr/bin/echoping forks = 5 offset = 50% step = 300 # The following variables can be overridden in each target section /^influx_.+/ = influx_location = In the basement extraopts = -some-letter-the-author-did-not-think-of fill = A ipversion = 4 pings = 5 priority = 6 size = 510 timeout = 1 tos = 0xa0 waittime = 1 # [...] *** Targets *** probe = EchoPingChargen # if this should be the default probe # [...] + mytarget # probe = EchoPingChargen # if the default probe is something else host = my.host /^influx_.+/ = influx_location = In the basement extraopts = -some-letter-the-author-did-not-think-of fill = A ipversion = 4 pings = 5 priority = 6 size = 510 timeout = 1 tos = 0xa0 waittime = 1
Variables
Supported probe-specific variables:
- binary
The location of your echoping binary.
Default value: /usr/bin/echoping
- forks
Run this many concurrent processes at maximum
Example value: 5
Default value: 5
- offset
If you run many probes concurrently you may want to prevent them from hitting your network all at the same time. Using the probe-specific offset parameter you can change the point in time when each probe will be run. Offset is specified in % of total interval, or alternatively as 'random', and the offset from the 'General' section is used if nothing is specified here. Note that this does NOT influence the rrds itself, it is just a matter of when data acquisition is initiated. (This variable is only applicable if the variable 'concurrentprobes' is set in the 'General' section.)
Example value: 50%
- step
Duration of the base interval that this probe should use, if different from the one specified in the 'Database' section. Note that the step in the RRD files is fixed when they are originally generated, and if you change the step parameter afterwards, you'll have to delete the old RRD files or somehow convert them. (This variable is only applicable if the variable 'concurrentprobes' is set in the 'General' section.)
Example value: 300
Supported target-specific variables:
- /^influx_.+/
This is a tag that will be sent to influxdb and has no impact on the probe measurement. The tag name will be sent without the "influx_" prefix, which will be replaced with "tag_" instead. Tags can be used for filtering.
Example value: influx_location = In the basement
- extraopts
Any extra options specified here will be passed unmodified to echoping(1).
Example value: -some-letter-the-author-did-not-think-of
- fill
The "-f" echoping(1) option.
Example value: A
- ipversion
The IP protocol used. Possible values are "4" and "6". Passed to echoping(1) as the "-4" or "-6" options.
Example value: 4
- pings
How many pings should be sent to each target, if different from the global value specified in the Database section. Note that the number of pings in the RRD files is fixed when they are originally generated, and if you change this parameter afterwards, you'll have to delete the old RRD files or somehow convert them.
Example value: 5
- priority
The "-p" echoping(1) option.
Example value: 6
- size
The "-s" echoping(1) option.
Example value: 510
- timeout
The "-t" echoping(1) option.
Example value: 1
Default value: 5
- tos
The "-P" echoping(1) option.
Example value: 0xa0
- waittime
The "-w" echoping(1) option.
Example value: 1
Authors
Niko Tyni <ntyni@iki.fi>
Notes
The udp variable is not supported.
See Also
Smokeping::probes::EchoPing