nvme-wdc-purge-monitor - Man Page

Send NVMe WDC Purge-Monitor Vendor Unique Command, return result

Synopsis

nvme wdc purge-monitor <device>

Description

For the NVMe device given, send a Vendor Unique WDC Purge-Monitor command and provide the status of the purge command​.

Expected status and description :-

Status CodeDescription
0x00Purge State Idle​.
0x01Purge State Done​.
0x02Purge State Busy​.
0x03Purge State Error : Purge operation resulted in error, power cycle required​.
0x04Purge State Error : Purge operation interrupted by power cycle or reset​.

The <device> parameter is mandatory and may be either the NVMe character device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1)​.

This will only work on WDC devices supporting this feature​. Results for any other device are undefined​.

On success it returns 0, error code otherwise​.

Options

No options yet​.

Examples

Nvme

Part of the nvme-user suite​.

Referenced By

nvme(1).

08/18/2026 NVMe Manual