nvme-resv-acquire - Man Page

Acquire an nvme reservation

Synopsis

nvme resv-acquire <device> [--namespace-id=<nsid> | -n <nsid>]
                        [--crkey=<crkey> | -c <crkey>]
                        [--prkey=<prkey> | -p <prkey>]
                        [--rtype=<rtype> | -t <rtype>]
                        [--racqa=<racqa> | -a <racqa>] [--iekey | -i]
                        [--output-format=<fmt> | -o <fmt>] [--verbose | -v]
                        [--timeout=<timeout>]

Description

The Reservation Acquire command is used to acquire a reservation on a namespace, preempt a reservation held on a namespace, and abort a reservation held on a namespace.

Options

-n <nsid>, --namespace-id=<nsid>

Override the nsid field. If using the admin character device, this parameter is required.

-c <crkey>, --crkey=<crkey>

Current Reservation Key: The field specifies the current reservation key associated with the host. If the IEKEY bit is set to ‘1’ in the command, then the CRKEY check succeeds regardless of the value in this field.

-p <prkey>, --prkey=<prkey>

Preempt Reservation Key: If the Reservation Acquire Action is set to 001b (i.e., Preempt) or 010b (i.e., Preempt and Abort), then this field specifies the reservation key to be unregistered from the namespace. For all other Reservation Acquire Action values, this field is reserved.

-t <rtype>, --rtype=<rtype>

Reservation Type: This field specifies the type of reservation to be created.

ValueDefinition
0hReserved
1hWrite Exclusive Reservation
2hExclusive Access Reservation
3hWrite Exclusive - Registrants Only Reservation
4hExclusive Access - Registrants Only Reservation
5hWrite Exclusive - All Registrants Reservation
6hExclusive Access - All Registrants Reservation
07h-FFhReserved
-a <racqa>, --racqa=<racqa>

Reservation Acquire Action: This field specifies the action that is performed by the command.

ValueDefinition
0Acquire
1Preempt
2Preempt and Abort
3-7Reserved
-i,  --iekey

Ignore Existing Key: If this bit is set to a 1, then the Current Reservation Key (CRKEY) check is disabled and the command shall succeed regardless of the CRKEY field value.

Indicator option, defaults to 0.

-o <fmt>, --output-format=<fmt>

Set the reporting format to normal, json or binary. Only one output format can be used at a time.

-v,  --verbose

Increase the information detail in the output.

--timeout=<timeout>

Override default timeout value. In milliseconds.

Examples

No examples yet

Nvme

Part of the nvme-user suite

Referenced By

nvme(1).

10/31/2024 NVMe Manual